Brandsweg 34 8077SK Hulshorst
(Dec. 14, 2024)
General Information
Registration Date: Dec. 14, 2024
Survey Date: Dec. 7, 2024
Valid Until: Dec. 7, 2034
Certificate Holder: BuildingLabel B.V.
Survey Type: Detailopname
Status: Vergunningsaanvraag/melding WKB
Calculation Type: NTA 8800:2024 (detailopname woningbouw)
Based on reference building: -
SBI Code: -
Project Name: -
Project Object: -
Building Information
Building Type: Vrijstaande woning
Building Subtype: -
Building Class: W
Construction Year: 2022
Thermal Zone Area: 166.27 m2
Compactness: 2.44
Energy Performance
Energy Class: A
Energy Index: -
Energy Need: 82.14 kWh/m².yr (EP1)
Primary Fossil Energy: 124.34 kWh/m².yr (EP2)
Renewable Energy Share: 0.0 % (EP3)
Temperature Exceedance: 1.70
Heat Demand: 80.55 kWh/m².yr
Energy Index (EMG Forfaitair): -
Primary Fossil Energy (EMG Forfaitair): None
Renewable Energy Share (EMG Forfaitair): -%
Energy Need Requirement: 83.21 kWh/m².yr (BENG1)
Primary Fossil Energy Requirement: 30.00 kWh/m².yr (BENG2)
Renewable Energy Share Requirement: 50.0 % (BENG3)
Temperature Exceedance Requirement: 1.20
Calculated CO2 Emission: 22.92
Calculated Energy Consumption: 124.34
Location Information
BAG Object ID: 0302010000054569
Building Detail Description: -