3225MA 3
(Jan. 13, 2026)
General Information
Registration Date: Jan. 13, 2026
Survey Date: Nov. 27, 2025
Valid Until: Nov. 27, 2035
Certificate Holder: Stichting Enexys
Survey Type: Detailopname
Status: Oplevering
Calculation Type: NTA 8800:2024 (detailopname utiliteitsbouw)
Based on reference building: -
SBI Code: -
Project Name: -
Project Object: -
Building Information
Building Type: -
Building Subtype: -
Building Class: U
Construction Year: 2024
Thermal Zone Area: 426.42 m2
Compactness: 2.27
Energy Performance
Energy Class: A++
Energy Index: -
Energy Need: 91.52 kWh/m².yr (EP1)
Primary Fossil Energy: 86.21 kWh/m².yr (EP2)
Renewable Energy Share: 30.5 % (EP3)
Temperature Exceedance: -
Heat Demand: 53.94 kWh/m².yr
Energy Index (EMG Forfaitair): -
Primary Fossil Energy (EMG Forfaitair): None
Renewable Energy Share (EMG Forfaitair): -%
Energy Need Requirement: 104.22 kWh/m².yr (BENG1)
Primary Fossil Energy Requirement: 40.82 kWh/m².yr (BENG2)
Renewable Energy Share Requirement: 30.0 % (BENG3)
Temperature Exceedance Requirement: -
Calculated CO2 Emission: 20.21
Calculated Energy Consumption: 86.20
Location Information
BAG Object ID: 1992010000017057
Building Detail Description: -