4812VJ 53-B2
(April 7, 2025)
General Information
Registration Date: April 7, 2025
Survey Date: Jan. 23, 2025
Valid Until: Jan. 23, 2035
Certificate Holder: Breuers & Cobelens
Survey Type: Basisopname
Status: Bestaand
Calculation Type: NTA 8800:2024 (basisopname woningbouw)
Based on reference building: -
SBI Code: -
Project Name: -
Project Object: -
Building Information
Building Type: Appartement
Building Subtype: Hoekmidden
Building Class: W
Construction Year: 2013
Thermal Zone Area: 138.76 m2
Compactness: 0.81
Energy Performance
Energy Class: A++
Energy Index: -
Energy Need: 62.21 kWh/m².yr (EP1)
Primary Fossil Energy: 71.88 kWh/m².yr (EP2)
Renewable Energy Share: 0.0 % (EP3)
Temperature Exceedance: -
Heat Demand: 36.91 kWh/m².yr
Energy Index (EMG Forfaitair): -
Primary Fossil Energy (EMG Forfaitair): None
Renewable Energy Share (EMG Forfaitair): -%
Energy Need Requirement: - kWh/m².yr (BENG1)
Primary Fossil Energy Requirement: - kWh/m².yr (BENG2)
Renewable Energy Share Requirement: - % (BENG3)
Temperature Exceedance Requirement: -
Calculated CO2 Emission: 14.18
Calculated Energy Consumption: 71.88
Location Information
BAG Object ID: 0758010000094750
Building Detail Description: -